NVIDIA Skyway MGA100-HS2 vs MGA400-XS2: Gateway Selection

NVIDIA Skyway MGA100-HS2 and MGA400-XS2 gateway selection overview

NVIDIA documents Skyway MGA100-HS2 as an appliance that routes Internet Protocol (IP) traffic between InfiniBand and Ethernet. It has eight fabric-side connections and eight Ethernet-side connections on ConnectX-6 VPI adapters, and the documented interfaces reach HDR and 200GbE respectively. MGA400-XS2 is a separate catalog and quote identity. Use the exact GA400 hardware guide, ordered interfaces and qualified cabling for that line before sizing a deployment around it. NVIDIA Skyway ordering manual · NVIDIA GA100 technical specifications

Compare the Skyway order codes for routing from an InfiniBand compute network to Ethernet storage. View full-size cover image.

Compare what the two order codes establish

Item MGA100-HS2 MGA400-XS2
Quote identity NVIDIA 920-9B020-00FA-0D2, documented in the OEM ordering table SwitchInfra catalog cross-reference 920-9B02D-00RG-CF0. Match the seller’s exact OPN and numeric label.
Hardware and power 2U appliance with two AC PSUs and eight dual-port ConnectX-6 VPI cards Request the exact hardware revision, rack and power configuration from the current quote and hardware reference.
Interface plan Eight InfiniBand and eight Ethernet sides. Validate negotiated rate and media per port. Obtain separate supported rates, port count, port modes and optics tables for the InfiniBand and Ethernet sides.
Operations Design the routed IP boundary, management access and failure behavior around GA100 documentation. Confirm the supported gateway software train, route behavior and failover mode for the offered configuration.

The GA100 hardware guide and SwitchInfra listings support the identity and scope above. A supplier’s quote for MGA400-XS2 should attach its version-specific technical documents before those interfaces become line items in the bill of materials. NVIDIA Skyway introduction · SwitchInfra MGA100-HS2 · SwitchInfra MGA400-XS2 catalog entry

MGA100-HS2 and MGA400-XS2 order-code comparison table

Compare the ordering identifiers, hardware, power and interfaces for the two Skyway gateways.

Documented application: routing from InfiniBand compute to Ethernet storage

NVIDIA’s GA100 networkwide deployment guide describes a Skyway gateway joined to InfiniBand on one side and an NVIDIA Onyx Ethernet switch on the other. The design includes different network-facing addresses and a virtual address on the InfiniBand side. It provides a concrete pattern for reaching Ethernet services from an InfiniBand compute network over Internet Protocol (IP). It is a vendor deployment example. The guide’s sample addresses and interface numbering are specific to its topology. NVIDIA Skyway networkwide deployment guide

For a 200GbE storage boundary, map the GA100’s 8 + 8 published port layout to the available InfiniBand and Ethernet attachments. Test return-route symmetry and service behavior with the selected links down. For a quote that uses MGA400-XS2, reuse that routing and acceptance plan as a requirements checklist. Obtain its own supported interface counts, speeds, software and media before copying the physical topology. NVIDIA GA100 specifications · SwitchInfra GA400 catalog identity

InfiniBand compute and Ethernet storage topology with multiple Skyway gateways

The topology traces traffic from the compute nodes through Skyway to the Ethernet storage network.

Where an InfiniBand-to-Ethernet gateway fits

Consider a compute cluster with a native InfiniBand fabric whose clients must reach an Ethernet storage service over IP. Start with the client subnet, gateway addresses and storage VLAN or routed subnet. Draw both directions of the traffic. Identify who advertises the return route and who owns traffic policy, addressing, monitoring and failover at the boundary. NVIDIA describes hardware-based forwarding of IP packets for GA100. If the workload depends on RDMA semantics across the boundary, document the required end-to-end transport and validate it through the actual application path. NVIDIA Skyway networkwide deployment guidelines

For sizing, record the simultaneous read and write load from real jobs, then reserve capacity under the failure you intend to tolerate. For example, a GA100 design with four confirmed 200GbE attachments on the Ethernet side has 800 Gb/s of nominal line-rate sum in one direction. Losing one attachment reduces that sum to 600 Gb/s. Actual usable throughput also depends on the InfiniBand ports, routing, traffic distribution, protocol overhead and storage service. Benchmark the two-sided design with the intended workload before planning a migration.

Redundant InfiniBand-to-Ethernet routing through two Skyway gateways

The routing diagram shows the default gateway, next hops and redundant paths.

Replacement decision and verification

Replacement decision. Keep a GA100 replacement on its verified two-sided IP routing design. A proposal to migrate from MGA100-HS2 to MGA400-XS2 is conditional on obtaining the exact GA400 interface and software documents and qualifying the complete gateway path. NVIDIA GA100 deployment example · SwitchInfra GA400 order-code reference

Before and after. Baseline the existing routes in both directions and service behavior from an InfiniBand compute client. Verify throughput and the agreed failure behavior with the proposed gateway and actual storage service. Keep the original route and a restoration plan until both forward and return paths pass under load.

Buying guide for a Skyway gateway

  • Appliance. Full legacy OPN, numeric SKU, hardware and gateway software revisions, rack kit and cord or feed requirements.
  • InfiniBand and Ethernet links. One row per physical connection with peer model, local and remote port IDs, optics or cable OPN at each end, mode, reach and connector.
  • Network services. Addressing, routes in both directions, MTU, redundancy and out-of-band access.
  • Acceptance. Normal-load and failure-state capacity, path and route recovery, and measured storage performance from a compute client.

Is a UFM appliance part of the same order?

UFM provides fabric management and telemetry on the deployment’s management paths. Skyway provides a routed data path at the boundary. A cluster can require both. Assign separate ports, acceptance criteria and failure tests to each role. NVIDIA UFM hardware overview · SwitchInfra cluster operations guide

Request a gateway configuration review with the intended order code, switch and storage models, link distances, required IP throughput, and the failover target. For a GA400 quote, include the numeric part number from the supplier and the current interface documentation.

Six additional Skyway ordering and deployment diagrams

Skyway order-code comparison and Ethernet storage path

The diagram pairs the gateway ordering checks with the compute-to-storage route.

Skyway gateway sizing and link selection

Plan gateway capacity around concurrent traffic, link rates and the interfaces available for the deployment.

MGA100-HS2 and MGA400-XS2 procurement checks

Review the interfaces, power requirements and accessories for the selected order code.

Skyway gateway deployment and variant checks

Match the device variant and port layout to the cables and rack available at the site.

NVIDIA Skyway gateway interface planning

Identify which interfaces carry cross-network traffic and which are needed for management.

Skyway connecting InfiniBand compute nodes to Ethernet storage

Trace the compute, gateway and storage links when planning capacity and redundancy.

Frequently asked questions

What should I test if a storage gateway link fails?

Exercise the storage operation from a compute client with a planned link unavailable. Capture the return route, remaining link capacity, path recovery and service behavior. Use a representative storage workload and state the assumed failure in the results. NVIDIA Skyway networkwide deployment guide

Which data do I need before sizing MGA400-XS2?

Get the exact hardware and port documentation for the quoted system, the approved software and media on both sides, and the target workloads’ traffic distribution. The channel or catalog order code is an identity for requesting those details. SwitchInfra MGA400-XS2 catalog entry

Acronyms and terms

  • IB means InfiniBand. HDR refers to the 200 Gb/s High Data Rate InfiniBand generation.
  • VPI means Virtual Protocol Interconnect. Check the mode of each configured ConnectX port.
  • IP means Internet Protocol. RDMA means Remote Direct Memory Access.
  • MTU means maximum transmission unit. BOM means bill of materials.

References and related reading