网络交换机

MQM9790-NS2F

NVIDIA QM9790 NDR InfiniBand switch (MQM9790-NS2F)

P/N:MQM9790-NS2FSKU: 920-9B210-00FN-0D0SwitchInfra item:7719品牌: NVIDIA
规格参数
封装类型1U
imageNoteManufacturer reference image. Included components and condition follow the selected item.
AirflowP2C
AC input200–240 VAC, 10 A, 50/60 Hz
ProtocolInfiniBand
Data cages32 × OSFP
Data ports64 × NDR 400 Gb/s
料号MQM9790-NS2F
Weight with two PSUs14.8 kg
工作温度0–35°C (forward P2C)
Manufacturer lifecycleMass Production
Owner-confirmed airflowP2C
Maximum power with active cables1,610 W
Typical power with passive cables (ATIS)640 W
管理方式
  • Externally managed (ordering table: unmanaged)

下单前确认

  • 确认准确的 SKU、料号、规格选项与数量。
  • 确认主机平台、端口、电气接口与固件兼容要求。
  • 付款前确认库存、交期、目的地与适用售后条款。
产品描述
64 NDR 400 Gb/s links across 32 OSFP cages in a 1U chassis. This externally managed configuration uses power-to-connector airflow.

产品问答

Do the two QM9790 airflow variants have the same temperature limit?

No. The hardware specifications list 0–35°C for forward airflow and 0–40°C for reverse airflow. NS2F is P2C/forward; NS2R is C2P/reverse. Use the range for the installed variant when reviewing cooling.

Can I select a replacement by appearance or wattage alone?

Use the manufacturer replacement-parts table for the complete switch model and order code. Matching dimensions, connector shape or PSU wattage alone does not establish compatibility.

How do MQM9790-NS2F and MQM9790-NS2R differ?

The public ordering table assigns power-to-connector airflow to NS2F and connector-to-power airflow to NS2R. Match the rack cooling plan and replacement FRUs to that choice.

What does unmanaged mean for QM9790?

QM9790 is the externally managed member of the family. NVIDIA distinguishes it from QM9700/QM9701 with onboard management and describes using UFM for fabric operations. Plan the external fabric-management system explicitly.

How many network ports does QM9790 provide?

The QM97XX ordering table lists 64 NDR ports using 32 OSFP cages. Count logical links separately from physical cages when planning the fabric.

How can an operator check the uptime of an unmanaged QM9790?

An NVIDIA Developer Forums reply suggests the mlxuptime utility against the switch LID and using OpenSM logs to inspect removal or discovery events. Validate commands and permissions against your software environment.

可以先描述需求,型号、主机或数量尚未确定也能咨询。

渠道与项目资料

推进客户的下一步决策

从现有产品组合、产品系列或不完整的项目清单出发,选择与你的职责对应的资料。

OA03 · NVIDIA

AI Ethernet、网卡及光模块和线缆互连。

920-9B210-00FN-0D0

BOM 与待决项梳理

保留原始料号与数量,同时整理影响项目决策的待确认事项。

从这些信息开始
现有清单、上传的 BOM 或简要需求,不完整的清单也可以提交。
用于准备
保留原始行号、待补信息、责任人及下一动作的待决项表。