NVIDIA Quantum-X800 Switches Compared: Q3200, Q3300, Q3400 and Photonics
Compare Quantum-X800 logical XDR ports, OSFP cages, rack cooling, AC or DC power and the Q3450-LD photonics procurement evidence.

NVIDIA’s Quantum-X800 lineup spans two separate 36-port switches in a Q3200-RA enclosure, 144-port pluggable systems such as Q3400-RA, and a co-packaged optics (CPO) Q3450-LD design. Each quoted eXtreme Data Rate (XDR) data port is rated up to 800 Gb/s, but the switch radix, connector count, power and facility requirements depend on the system. Use the complete ordering code and connection schedule before allocating topology or ordering optics. NVIDIA Quantum-X800 switch datasheet, pp. 2–3 · NVIDIA Q32xx and Q34xx hardware manual
Review the installation and deployment choices for Q3200, Q3300, Q3400 and photonic switches. View full-size cover image.
Compare Quantum-X800 ordering and installation choices
| Candidate | XDR ports and data connectors | Rack, cooling and power | Ordering evidence |
|---|---|---|---|
| Q3200-RA, 920-9B34F-00RX-FS0 | 36 logical XDR ports over 18 OSFP cages per internal switch. Two independent switches share one enclosure. | 2U, air-cooled, C2P, four PSUs. Power cords are separate. | Exact NVIDIA ordering row |
| Q3300-LD, request reference 920-9B36F-00NX-GS0 | NVIDIA describes the model as 144 XDR ports over 72 OSFP cages. | 3U, liquid-cooled, pluggable media. Confirm the exact input power from the order-specific documents. | NVIDIA model-level evidence and SwitchInfra catalog cross-reference |
| Q3400-RA, 920-9B36F-00RX-8S0 | 144 logical XDR ports over 72 OSFP cages. | 4U, air-cooled, C2P, eight AC power supplies. Power cords are separate. | Exact NVIDIA ordering row |
| Q3401-RD, 920-9B36P-00RX-8S0 | 144 logical XDR ports over 72 OSFP cages. | 4U, air-cooled, C2P, 48V DC busbar. | Name and ordering code as shown in the hardware manual |
| Quantum-X Photonics quote with prefix 920-9B36M-00MX | Q3450-LD has 144 logical XDR ports. NVIDIA gives conflicting counts for physical MPO connectors. | NVIDIA documents a 4U liquid-cooled platform with 48V DC for Q3450-LD. Obtain the ordered cooling split and power requirements. | The OEM manual lists the prototype suffix 8ES. Confirm the commercial suffix, model name and lifecycle status on a signed quote. |
If the request shows only 920-9B36M-00MX-8S…, confirm the final character and the model printed on the label. SwitchInfra lists 920-9B36M-00MX-8S0 as Q3452-LD. NVIDIA’s public manual lists 920-9B36M-00MX-8ES as Q3450-LD. Use the documentation for the exact shipped variant when qualifying its power, optics and spares. SwitchInfra photonics catalog entry · NVIDIA Q32xx/Q34xx ordering and prototype table
How many physical MPO connectors does Q3450-LD use?
The NVIDIA ordering and specifications pages list 144 MPO connectors. The cabling chapter describes 72 physical MPOs with two independent XDR links per connector. Both describe a 144-port switch. Obtain the faceplate drawing, supported cable and connector mapping, and full hardware revision for the exact quote before sizing the fiber order. The public 8ES prototype reference and the 8S0 catalog entry have different identifiers. NVIDIA XDR ordering information · NVIDIA Q3450-LD specifications · NVIDIA Q3450 cabling and port notation
Use the matrix to review switch ports, rack installation, cooling and power requirements for each chassis.
Ten pairwise decisions for Quantum-X800 chassis
Start with the logical ports available inside a switching domain. Then compare rack power, cooling and the replaceable optical boundary. The entries below compare the documented Q3450-LD photonics family as a reference when reviewing a Q345x quote. Resolve the full suffix of the offered photonics line before specifying its parts. NVIDIA Quantum-X800 system specifications, pp. 2–3 · NVIDIA exact XDR order rows
| Chassis pair | Selection and test that change |
|---|---|
| Q3200-RA vs Q3300-LD | The 2U Q3200 offers two 36-port switching domains. The 3U Q3300-LD offers a 144-port pluggable domain and needs liquid cooling. Before changing the design, verify the Q3300-LD feed and recompute the uplink allocation. |
| Q3200-RA vs Q3400-RA | Both are air-cooled pluggable choices. Q3400-RA provides a single 144-port switch. Choose it when that spine radix is required and the rack can support its 4U AC configuration. |
| Q3200-RA vs Q3401-RD | From the two switch instances in a 2U AC enclosure, a move to Q3401-RD changes radix and introduces a 4U 48V DC busbar installation. Validate the rack before committing a 144-port design. |
| Q3200-RA vs Q3450-LD family | Compare two small pluggable leaves with a high-density photonics chassis. The latter changes the switch connector, cooling and optic service model. Verify exact suffix, MPO and external laser service before sizing it. |
| Q3300-LD vs Q3400-RA | Both are documented at 144 XDR data ports over 72 OSFP cages. Compare 3U liquid-cooled Q3300-LD against the 4U air-cooled AC Q3400-RA. Confirm liquid supply and the Q3300 order-specific feed. |
| Q3300-LD vs Q3401-RD | Both have a 144-port pluggable layout. Q3401-RD has a documented air-cooled DC busbar configuration. Q3300-LD needs liquid cooling and manufacturer confirmation of its exact feed. |
| Q3300-LD vs Q3450-LD family | Compare two liquid-cooled paths to 144 logical XDR ports. The Q3300 uses pluggable OSFP and the Q3450-LD reference uses MPO for co-packaged optics. The service spares and cable path change with the optical design. |
| Q3400-RA vs Q3401-RD | Same 144-port pluggable layout and C2P air cooling. Q3400-RA specifies eight AC PSUs and Q3401-RD a 48V DC busbar. Verify rack feed, mounting and cord requirements before substitution. |
| Q3400-RA vs Q3450-LD family | The AC air-cooled OSFP design and the liquid-cooled DC photonics reference have different installation and fiber requirements. Preserve logical port counts when remapping the fiber plant. |
| Q3401-RD vs Q3450-LD family | The Q3401-RD air-cooled busbar switch retains pluggable OSFP service. The photonics reference changes to liquid cooling and direct MPO. Confirm the exact variant’s liquid and optical interface before reusing a DC cabinet position. |
Documented application: Quantum-X800 in production and in a B300 reference design
Public production deployment. NVIDIA reports that Azure’s GB300 NVL72 production cluster for OpenAI uses Quantum-X800 InfiniBand and ConnectX-8 to connect racks. Within the racks, NVLink serves a different connection role. This publication establishes platform adoption for an AI inference cluster. Use the reference architecture and ordering manual for chassis-level selection. NVIDIA report on Microsoft’s Azure deployment
Manufacturer reference architecture. NVIDIA names Q3400-RA in the AC-powered DGX B300 SuperPOD XDR compute fabric. Its documented rack role is a starting point when choosing between 144-port air-cooled pluggable designs. A Q3401-RD proposal keeps the corresponding port-count class and changes the facility feed. A Q3200-RA mixed-generation edge uses separate switch-instance budgets and has a different place in the topology. DGX B300 XDR key components · NVIDIA Q3200 design considerations
This platform reference shows the relationship between Blackwell compute, ConnectX-8 adapters and the Quantum-X800 fabric.
Published Q3400-RA acceptance measurements in a 36-server B300 cluster
Integrator NADDOD reports a deployed compute network of 36 NVIDIA B300 servers and six Q3400-RA switches. Its commissioning report describes the ConnectX-8 four-plane design and records separate single-link write and multi-server collective communication tests. The source reports the delivered configuration and its measurements. It leaves the prior chassis and a matched pre-upgrade test unspecified. NADDOD B300 XDR deployment, sections 2.2.1 and 3
| Commissioning measurement | Integrator-reported result | What it helps an operator verify |
|---|---|---|
| CPU Direct single-link write | About 440–470 Gb/s | Check the CPU-to-adapter data path and interpret the result with its PCIe configuration. |
| GPU remote direct memory access (RDMA) single-link write | About 787.7 Gb/s average | Verify the end-to-end GPU write path for the documented XDR link. |
| NVIDIA Collective Communications Library (NCCL) AllReduce across 36 servers, messages larger than 256 MB | Approximately 470–480 GB/s algorithm bandwidth and 820 GB/s bus bandwidth | Record the collective, message phase and metric definition. Collective bus bandwidth and single-link write throughput use different units and test scopes. |
For a Q3400-RA replacement or expansion, agree the target workload, host data path and message sizes before testing. Verify the physical link, error counters and recovery behavior alongside the throughput results. These figures are a reference for commissioning that design. Use your own measured baseline and acceptance thresholds for a self-comparison. NADDOD test methods and results, sections 3.1–3.3 · NADDOD public test summary · NVIDIA Quantum-X800 supported interconnects
Why the Q3300-LD power line needs its own approval
NVIDIA’s Quantum-X800 platform solution overview describes Q3300-LD as DC-powered. The switch datasheet’s system specifications table shows a 200–240 VAC feed for Q3300-LD. The documents agree on the switch’s liquid-cooled, pluggable role. Resolve the input for the exact offered serial or OPN with the manufacturer’s rack integration documentation before releasing busbars, PDUs, cords or the cooling assembly. NVIDIA Quantum-X800 platform overview, Q3300-LD section · NVIDIA switch datasheet, system specifications · SwitchInfra Q3300-LD catalog entry
Choose the topology and optical path
Use Q3200-RA when two 36-port switching domains fit the design. Budget the cage, port and uplink assignments independently for A and B. The pair shares a chassis, so a design that must tolerate losing the enclosure needs separate physical failure domains. Use Q3400-RA or Q3401-RD when the application and topology benefit from a single 144-port switch and the corresponding rack feed has been qualified. NVIDIA NVOS Q3200 design considerations
For a pluggable XDR link, record the exact port, OSFP module or cable, lane mode, endpoint form factor, fiber type and connector. For the documented photonics design, record the switch-side MPO interface, cable path, peer optic and external laser source service plan. Budget the dedicated fabric management port separately from the data cages and confirm any NDR coexistence link against the current port-by-port support guidance. NVIDIA XDR cable installation and CPO topology · NVIDIA accessory and replacement part list
Trace optical connections through the leaf-spine fabric and check service access along the path.
Replacement decision and verification
Replacement decision. For an existing XDR spine, substituting Q3401-RD for Q3400-RA requires a documented DC rack installation even when the logical port map can be preserved. For a Q3300-LD quote, resolve the order-specific power conflict before approval. A Q3200 pair of internal switch instances and a photonics chassis each change the topology or optical service plan. NVIDIA XDR order rows · Quantum-X800 system specifications
Before and after. Baseline each rail’s working port assignment, supported optic and management attachment. After the change, verify the negotiated speed on both ends and prove reachability through the intended fabric management path. Repeat a representative load and failure test before migrating the remaining rails.
Buying guide for a Quantum-X800 switch
Send the exact OPN, 2U/3U/4U rack envelope, cooling and facility feed, required 800 Gb/s endpoint count per switching domain, and expected NVOS and UFM versions. Include a line for each peer and any links that need to run in a different mode. Ask the seller to confirm the shipped hardware revision and sourcing status in writing. SwitchInfra XDR fabric planning and BOM examples
Frequently asked questions
How should I size the spine if both Q3200 internal switches are used?
Give each internal switch an independent logical port schedule. Allocate its host links, spine uplinks and reserves within its own 36-port budget. Include the shared chassis in the failure model and use separate physical fault domains where the fabric requires them. NVIDIA NVOS design considerations for Q3200
What happens to the optics budget when the switch uses photonics?
Build a new fiber schedule around the switch’s direct fiber interfaces, allowed peer optics and model-specific external laser source. Get the complete part number, hardware revision and maintenance procedure before buying MPO assemblies or spares. NVIDIA Q3450 CPO topology and cable details
Acronyms and terms
- XDR means eXtreme Data Rate, 800 Gb/s per link in the documented full-rate mode. NDR means Next Data Rate, the preceding 400 Gb/s generation.
- OSFP means Octal Small Form Factor Pluggable. MPO means multi-fiber push-on.
- CPO means co-packaged optics. ELS means external laser source.
- NVOS is NVIDIA’s network operating system. UFM means Unified Fabric Manager. PSU means power supply unit.
- RDMA means remote direct memory access. NCCL means NVIDIA Collective Communications Library. Gb/s counts gigabits per second and GB/s counts gigabytes per second.