NVIDIA SN2201 vs SN3420: 1GbE Management or 25GbE Server Access?

Compare SN2201 and SN3420 access ports, plus all six SN2201 variant pairings for airflow and AC, dual DC or MGX busbar power.

SwitchInfra•Nov 23, 2026
NVIDIA SN2201 management and SN3420 server access comparison

Choose SN2201 for an out-of-band (OOB) network with 48 copper 1GbE management connections and four QSFP28 uplink cages. Choose SN3420 when servers or appliances need 25GbE SFP28 access and the switch needs up to twelve QSFP28 uplink cages. Both fit a nominal 1U space and offer 100GbE uplinks. The endpoint media, access rate, rack dimensions and ordered power version determine the purchase. NVIDIA SN2201 introduction · NVIDIA SN3000 specifications, SN3420

Compare 1GbE out-of-band management and 25GbE server access when selecting the switch. View full-size cover image.

SN2201 and SN3420 ordering comparison

The airflow terms are power-to-connector (P2C) and connector-to-power (C2P). Read the part number against the rack’s intake side. The current NVIDIA hardware ordering tables provide the confirmed numeric identifiers. PNY’s hardware portfolio lists MSN2201-CBARC and its port layout. A separate channel listing reports dual DC power, so confirm that specification for the offered unit. NVIDIA SN2201 ordering information · NVIDIA SN3420 ordering information · PNY switch hardware portfolio, p. 5 · Servants CBARC listing · Tech2000 CBARC order-code listing

Legacy order code NVIDIA numeric SKU Ports Airflow and power
MSN2201-CB2FC 920-9N110-00F1-0C0 48 × 1GbE RJ45 and 4 × QSFP28 P2C, dual AC, short-depth 4-post rack option
MSN2201-CB2RC 920-9N110-00R1-0C0 48 × 1GbE RJ45 and 4 × QSFP28 C2P, dual AC, short-depth 4-post rack option
MSN2201-CSMRC 920-9N110-00R1-NC0 48 × 1GbE RJ45 and 4 × QSFP28 C2P, 48V DC busbar for MGX
MSN2201-CBARC 920-9N110-00R1-AC0, channel reference 48 × RJ45 and 4 × 100GbE QSFP28 in the PNY portfolio C2P. The channel listing specifies dual DC PSUs. Confirm voltage, connector and mounting on the exact quote.
MSN3420-CB2FC 920-9N213-00F7-0C0 48 × SFP28 and 12 × QSFP28 P2C, dual AC, Cumulus Linux order code
MSN3420-CB2RC 920-9N213-00R7-0C0 48 × SFP28 and 12 × QSFP28 C2P, dual AC, Cumulus Linux order code

NVIDIA SN2201 front and rear panels with 1GbE management ports

The panel views show the SN2201 copper access ports, uplinks and rear components.

NVIDIA SN3420 front panel with 25GbE SFP28 ports

The panel view shows the SN3420 server-facing ports and the uplinks used to reach the rest of the network.

Six pairwise comparisons for the SN2201 order codes

All four order codes are documented as 1U configurations with 48 RJ45 access ports and four QSFP28 uplinks, using NVIDIA’s ordering rows for CB2FC, CB2RC and CSMRC and PNY’s hardware portfolio for CBARC. Use the pair below to narrow the rack choice. For CBARC, the dual-DC description and numeric code are channel references. Verify the offered unit before assigning a power feed or spare. NVIDIA SN2201 and SN2201_M ordering tables · PNY switch hardware portfolio, p. 5 · Servants CBARC listing · Tech2000 CBARC order-code listing

MSN2201-CB2FC vs MSN2201-CB2RC

Conditional chassis replacement in an AC rack. Approve the opposite airflow and resulting rack orientation first.

Both are short-depth dual-AC switches with the same port layout and 4-post rail configuration. The CB2FC takes in air on the power side and exhausts toward the connectors. The CB2RC takes in air on the connector side and exhausts toward the power supplies. Match the switch intake to the cold aisle and confirm which side needs room for RJ45 cable bundles and QSFP28 uplinks. For an installed switch replacement, use the airflow direction on the chassis and FRU labels. NVIDIA SN2201 ordering information

MSN2201-CB2FC vs MSN2201-CBARC

CBARC substitution requires a verified DC installation and a connector-side intake. Obtain the order-specific power and mounting documents.

CB2FC is the documented dual-AC, P2C choice. The CBARC channel listing describes dual DC and C2P. On a replacement request, verify both changes independently. Confirm the facility feed against the offered CBARC’s input label, then check that the connector side faces the rack’s cooling intake. If the site requires dual AC and a power-side intake, the CB2FC ordering row meets those requirements. NVIDIA SN2201 AC order codes · CBARC distributor specification

MSN2201-CB2FC vs MSN2201-CSMRC

This is a rack migration. An AC-to-MGX change needs an approved 48V DC busbar, MGX mounting and a new airflow check.

CB2FC uses dual AC, a short-depth 4-post rail configuration and P2C airflow. CSMRC specifies an MGX rack, a 48V DC busbar and C2P airflow. Moving the same out-of-band network between these two chassis changes the power delivery, rack mount and intake side. Preserve the BMC port schedule and validate the new cabinet layout and management uplink routing. NVIDIA SN2201 and SN2201_M order codes

MSN2201-CB2RC vs MSN2201-CBARC

Hold the substitution until the exact CBARC power input and mount are confirmed. Their shared intake direction only settles the airflow check.

Both are listed with connector-side intake. Check the power feed first. NVIDIA documents dual AC for CB2RC, while the channel lists dual DC for CBARC. A purchasing request that specifies only C2P, 48 RJ45 ports and four QSFP28 uplinks leaves both codes in scope. Record the full OPN and input feed. Ask for the CBARC nameplate, connector and rail details before choosing that configuration. NVIDIA SN2201 ordering information · CBARC distributor specification

MSN2201-CB2RC vs MSN2201-CSMRC

This is a power and mounting migration. The C2P orientation can stay in the design if both cabinets support it.

Both use C2P airflow. The CB2RC order line specifies dual AC and a 4-post rail kit. The CSMRC order line specifies the SN2201_M for an MGX 48V DC busbar rack. Choose the documented order code that matches the facility’s power delivery and mounting system. For an AC-to-MGX migration, check the management link reach and the cable service clearance after the new switch is placed. NVIDIA SN2201 and SN2201_M ordering tables

MSN2201-CBARC vs MSN2201-CSMRC

Approve only against the exact DC input and mechanical drawings. Treat the channel-described dual-DC supplies and the documented MGX busbar as separate installations.

The CBARC is described in channel material as C2P with two DC power supplies. The CSMRC has a manufacturer-documented MGX 48V DC busbar mount. For a DC rack inquiry, ask for the exact CBARC input voltage, feed connector, mounting drawing and supported spare PSU. For CSMRC, check the rack’s busbar interface and mounting against the NVIDIA manual. Match the offered numeric SKU and installation documentation before approving a substitution. CBARC distributor specification · NVIDIA SN2201_M ordering information

After an SN2201 swap. Compare upstream link rate and management gateway reachability with the pre-change baseline. From the approved management network, verify the intended baseboard management controller (BMC) and infrastructure endpoints are still reachable. Test the required recovery path before completing the change. NVIDIA DGX B300 OOB reachability checks

SN3420 airflow comparison and SN2201-to-SN3420 pairs

MSN3420-CB2FC and MSN3420-CB2RC share the 48 SFP28 and 12 QSFP28 configuration and dual AC supplies. Mount CB2FC with its power side at the cool intake and CB2RC with its connectors at the cool intake. Cross-family selection starts with the endpoint medium and then considers the cabinet. NVIDIA SN3420 ordering table · NVIDIA SN2201 ordering table

Exact order-code pair What changes in this application
MSN3420-CB2FC vs MSN3420-CB2RC Same 25GbE server connectivity and dual AC. Choose the exhaust direction that keeps the switch aligned with the aisle.
MSN2201-CB2FC vs MSN3420-CB2FC Both are P2C and dual AC. Use the 2201 for copper BMC access and the 3420 for SFP28 server access. Check rack depth and QSFP28 uplink density.
MSN2201-CB2FC vs MSN3420-CB2RC The service changes from copper OOB to SFP28 server access and the intake moves to the connector side. Recheck media, cabinet orientation and rail clearance.
MSN2201-CB2RC vs MSN3420-CB2FC Both use dual AC. A move from 1GbE BMC access to 25GbE server connectivity also reverses the airflow. Keep the management plane connected during the migration.
MSN2201-CB2RC vs MSN3420-CB2RC Both are C2P and dual AC. Match copper RJ45 or SFP28 access to the attached devices. The 3420 has twelve uplink cages and the 2201 has four.
MSN2201-CBARC vs MSN3420-CB2FC The CBARC candidate is C2P with dual DC in the channel documentation. The 3420 offers P2C dual AC for SFP28 servers. Verify the CBARC’s input and both port schedules before designating either device as a spare.
MSN2201-CBARC vs MSN3420-CB2RC C2P is shared. The CBARC is a copper management candidate with a channel-reported DC feed. The 3420 is a documented dual-AC SFP28 switch. Validate the input feed as well as the access interface.
MSN2201-CSMRC vs MSN3420-CB2FC The OOB switch uses MGX DC busbar and C2P. The 25GbE server switch uses dual AC and P2C. The cabinet feed, airflow and access media all need their own checks.
MSN2201-CSMRC vs MSN3420-CB2RC The intake is C2P on both. Confirm MGX busbar and copper ports for the 2201 or an AC power plan and SFP28 endpoints for the 3420.

SN2201 and SN3420 order-code, airflow and substitution comparison

Check the order-code suffix, airflow and interfaces before specifying a replacement.

Documented application: DGX SuperPOD out-of-band management

In NVIDIA’s DGX H200 SuperPOD reference architecture, SN2201 switches carry the out-of-band (OOB) connections for DGX and management servers, storage, network devices and rack power distribution units (PDUs). This network reaches management interfaces independently of the compute fabric. In the DGX B300 DC-busbar reference architecture, NVIDIA’s OOB component table lists both 920-9N110-00R1-0C0 (MSN2201-CB2RC) and 920-9N110-00R1-NC0 (MSN2201-CSMRC). The ordering manual identifies the first as dual AC and the second as 48V DC busbar for MGX. DGX H200 SuperPOD network fabrics · DGX B300 reference bill of materials, OOB Ethernet network · SN2201 ordering information

For a rack following that design, dedicate the copper access ports to baseboard management controllers (BMCs) and infrastructure management. Choose CB2RC for a qualified C2P AC rack or CSMRC for a qualified MGX busbar rack. A separate AC rack with its intake on the power side can use the documented CB2FC option, subject to fit. For an installed CBARC replacement, gather the hardware nameplate and power connection before changing the cabinet design. The B300 component list establishes the AC and MGX order codes used in the reference architecture. It leaves each site’s final cable schedule, airflow and failure tests to the deployment team. DGX B300 deployment guide, OOB network

Match the switch to the links it will terminate

SN2201 for a 1GbE out-of-band rack. List server BMCs, infrastructure controllers and switch management interfaces before counting transceivers. For example, 32 BMCs, four switch management ports and two facility controllers consume 38 copper access ports, leaving ten for growth. The QSFP28 uplink cages are a separate budget. An aggregation link still needs a supported module or cable at both ends, a known management VLAN and an outage test for the remote access path.

SN3420 for 25GbE server-facing top of rack. Thirty-two servers at 25GbE create a nominal 800 Gb/s edge bandwidth budget. Eight 100GbE uplinks would equal that budget in line-rate sum, leaving four QSFP28 cages before growth and role reservations. A cut in the number of available uplinks changes this ratio. Check the endpoint optics or DACs, FEC and breakout modes against the intended software release and hardware. NVIDIA SN3000 specifications

SN2201 and SN3420 network selection checklist

Match endpoint speeds, uplinks and rack airflow to the network being deployed.

Buying guide for SN2201 and SN3420

Before requesting a quote, send the expected endpoint count and type, rack depth and mounting system, power architecture, desired airflow, and a list of uplinks and peer ports. SwitchInfra cluster infrastructure operations

The SN2201 chassis reference image

Supplier reference image of the NVIDIA SN2201 switch chassis

This supplier image shows the chassis exterior. Use the manufacturer specifications cited in the guide for port and chassis details.

Frequently asked questions

How do I select CB2FC or CB2RC if the rack’s front and rear are hard to label?

Identify where cool air physically enters the rack. CB2FC takes air at the power side and CB2RC takes it at the connector side. Compare the faceplate, service direction and cable clearance before choosing the exact SKU. NVIDIA SN2201 ordering and airflow links

Can an SN2201 OOB uplink operate below 100GbE?

NVIDIA lists specific 40GbE and breakout options in the system introduction. Confirm the exact port mapping, supported assembly and peer speed before ordering the uplink. Reserve the four physical QSFP28 positions separately from the copper access count. NVIDIA SN2201 speed and interface table

How should I quote an MSN2201-CBARC replacement?

Use the full OPN and the channel identifier 920-9N110-00R1-AC0 as cross-references. Get the chassis label, allowed input voltage, connector and mounting hardware in writing. For the documented MGX busbar installation, confirm the separate CSMRC order and rack drawing. CBARC channel identifier · NVIDIA SN2201_M order row

Acronyms and terms

  • OOB means out-of-band. BMC means baseboard management controller.
  • ToR means top-of-rack. PDU means power distribution unit.
  • P2C means power-to-connector. C2P means connector-to-power.
  • AC means alternating current. DC means direct current. MGX refers to NVIDIA’s modular system and rack architecture.
  • SFP28 is Small Form Factor Pluggable for the 25 Gb/s class used here. QSFP28 is Quad Small Form Factor Pluggable in the 100 Gb/s class used here.