NVIDIA SN5400 vs SN5600D vs SN5610: Which Spectrum-4 Switch Fits?

Compare Spectrum-4 64-port QSFP56-DD and OSFP configurations, SN5400 airflow, and SN5600D DC versus SN5610 AC ordering codes.

SwitchInfra•Nov 23, 2026
NVIDIA SN5400, SN5600D and SN5610 Spectrum-4 comparison

SN5400 exposes 64 × 400GbE QSFP56-DD data cages, while SN5600D and SN5610 expose 64 × 800GbE Octal Small Form Factor Pluggable (OSFP) data cages on the models compared here. Choose SN5600D 920-9N42F-00RI-KC0 when the qualified installation calls for an MGX 48V DC busbar. Choose SN5610 920-9N42F-00RI-3C1 when the plan calls for the four-PSU AC variant. The full ordering code determines the rack plan. NVIDIA Spectrum-4 SN5000 ordering information · NVIDIA SN5000 specifications

Use the Spectrum-4 overview to compare port speeds, optical connections and rack requirements. View full-size cover image.

Spectrum-4 ordering matrix

The rows below follow NVIDIA’s ordering information. All four order lines describe 2U systems and Cumulus Linux authentication. The source’s two SN5400 rows express the small-port line differently. If these ports are used in the network plan, confirm the physical layout and mode for the quoted chassis. NVIDIA SN5000 ordering tables by model

Model and NVIDIA SKU Main data cages Airflow Power and rack
SN5400 920-9N42C-00FB-7C0 64 × 400GbE QSFP56-DD P2C 2 AC PSUs, tool-less rail kit. Order row lists 2 SFP28 ports.
SN5400 920-9N42C-00RB-7C0 64 × 400GbE QSFP56-DD C2P 2 AC PSUs, tool-less rail kit. Order row describes the small ports as 1 × 2-port SFP28.
SN5600D 920-9N42F-00RI-KC0 64 × 800GbE OSFP C2P 48V DC busbar, MGX mount and mounting rails, 1 SFP28 in the order row
SN5610 920-9N42F-00RI-3C1 64 × 800GbE OSFP C2P 4 AC PSUs, tool-less rails, 2 SFP28 in the order row

The older AC SN5600 numeric SKU 920-9N42F-00RI-7C0 has its own row and EOL status in the manual. The different final segments identify different rack and power configurations. Ask the supplier to put the exact number and software entitlement in the quote. NVIDIA SN5600, SN5600D and SN5610 ordering tables

Spectrum-4 order-code comparison for SN5400, SN5600D and SN5610

Match the switch order code with its port count, interface speed and installation requirements.

Six pairwise comparisons across the Spectrum-4 order codes

The two SN5400 orders share the same main 64 × 400GbE data layout. The 800GbE orders share main port count and C2P direction, with very different installation requirements. NVIDIA SN5000 ordering table · Main data interfaces and port modes

Exact comparison Situation and decision
920-9N42C-00FB-7C0 vs 920-9N42C-00RB-7C0 Same 400GbE data port and dual AC concept. Use FB for P2C or RB for C2P. Confirm the ordering row’s auxiliary SFP28 presentation if those ports participate in management.
920-9N42C-00FB-7C0 vs 920-9N42F-00RI-KC0 A P2C AC 400GbE QSFP56-DD leaf and a C2P MGX DC 800GbE OSFP leaf need different facilities and interconnects. Qualify the cabinet and native 800GbE peer before migrating.
920-9N42C-00RB-7C0 vs 920-9N42F-00RI-KC0 Both draw air from the connector side. The 800GbE upgrade changes AC to a DC busbar and the main data cages from QSFP56-DD to OSFP. Recheck every retained 400GbE handoff.
920-9N42C-00FB-7C0 vs 920-9N42F-00RI-3C1 Both use AC, with two versus four supplies in the order rows. The 800GbE option also reverses airflow to C2P. Validate cabinet load and new cable placement.
920-9N42C-00RB-7C0 vs 920-9N42F-00RI-3C1 Both are C2P AC options. Choose according to the peer cage and link budget first, then confirm the different PSU count and redundancy design.
920-9N42F-00RI-KC0 vs 920-9N42F-00RI-3C1 SN5600D and SN5610 share 64 OSFP cages and C2P. The former needs 48V DC MGX mounting. The latter specifies four AC PSUs and its own rails. Confirm the power architecture and SFP28 ports in the bill of materials.

Documented applications: Spectrum-4 in xAI and in DGX B300

NVIDIA’s public report on xAI Colossus names Spectrum-X Ethernet as its scale-out networking platform. It is an example of an operating AI training cluster. Use NVIDIA’s model and part-specific documents to select ports and rack power for another installation. NVIDIA’s xAI Colossus deployment report

In the DGX B300 SuperPOD DC-busbar reference design, the component list identifies 920-9N42F-00RI-KC0 for compute, storage and in-band Ethernet switching roles. The SN5000 manual lists that code as SN5600D. For an AC equipment room, SN5610 provides an 800GbE starting point with a different power design. A 400GbE server or storage fleet may instead call for a qualified native QSFP56-DD layout on SN5400. Compare the actual host link modes and facility configuration before choosing. DGX B300 reference components by fabric · SN5000 order-code definitions

How to decide between 400GbE and 800GbE

Start with the required port speeds at the servers and at the spine. In a hypothetical 32-host design at 400GbE per host, the host-side line-rate sum is 12.8 Tb/s. It would take 32 same-rate uplinks to match that on an SN5400, consuming its 64 main cages if every link is native 400GbE. Sixteen 800GbE uplinks could supply the same nominal uplink bandwidth on a qualified 800GbE platform. The required number of host-side cages then depends on the approved 400GbE presentation, lane modes and cabling. The switch, adapter and media support tables establish which of those arrangements are available. NVIDIA SN5000 data interface table · NVIDIA SN5000 cable installation and splitter options

Retained 400GbE plant can favor SN5400 where the optics and peers are supported and capacity is adequate. An 800GbE leaf design needs its own OSFP and endpoint compatibility review, even if some access links operate at 400GbE. Budget the cable type and cooling style on both sides, and record the intended lossless Ethernet policy and supported software in the same bill of materials.

Spectrum-4 400GbE and 800GbE link planning

Plan the port speeds and optics on both ends of each link before selecting a switch.

Replacement decision and verification

Replacement decision. The two SN5400 air directions can be evaluated against the same 400GbE port plan, with the rack intake and exact auxiliary SFP28 interfaces checked independently. An SN5400-to-800GbE upgrade needs a new media and port-mode plan. Moving between the 800GbE SN5600D and SN5610 requires matching the target cabinet’s busbar or AC installation. NVIDIA SN5000 order rows · Supported SN5000 data interfaces

Before and after. Record the current endpoint speeds, FEC, lane mode and management ports before ordering cables. Verify the retained links and new uplinks on the replacement, including management reachability and the designed capacity with a feed or upstream path unavailable.

Buying guide for an SN5400, SN5600D or SN5610

Ask facilities to confirm MGX busbar or AC rack delivery, space, total load and remaining capacity during a feed failure. Give purchasing the numeric SKU and expected cable directions, and give network engineering the endpoint map, speed and FEC per link, software target and optics list. Verify the specified PSU and fan FRUs against the model’s current table. NVIDIA SN5000 accessory and replacement parts · SwitchInfra AI Ethernet fabric design

Frequently asked questions

Which number identifies the B300 DC-busbar switch?

The B300 reference component list uses 920-9N42F-00RI-KC0 on the DC Spectrum-4 switch rows. The hardware manual names that SKU SN5600D. Add the exact number to the quote along with the MGX mount. DGX B300 reference components · SN5000 order table

What changes when I keep 400GbE endpoints on a new 800GbE design?

Determine each endpoint’s electrical lane mode and approved module or breakout first. Then recompute physical cage count and uplink bandwidth for the new media. Verify what happens to retained paths when a spine is offline. NVIDIA SN5000 data interfaces and supported modes

Acronyms and terms

  • QSFP56-DD is the double-density QSFP form factor documented for the SN5400 main ports.
  • OSFP means Octal Small Form Factor Pluggable. SFP28 is the 25Gb/s-class Small Form Factor Pluggable used here for auxiliary links.
  • MGX denotes NVIDIA’s modular rack architecture. PSU means power supply unit.
  • AC and DC mean alternating and direct current. C2P and P2C are the two airflow directions.