Technical selection

Choose AI Network Cables by the Complete Link

Choose NVIDIA LinkX optics and cables by exact PN, both ports, connector polish, fiber grade and breakout mapping; turn the result into a link-by-link RFQ.

Editorial Team•Nov 16, 2026

Find the right decision page

Use this LinkX guide to choose the kind of connection and describe the whole path. Then move to the page that resolves the remaining question.

Decision Work on this page Continue with
How should the fabric serve the workload? Identify the connection’s role in the topology AI Ethernet fabric plan
Which adapter function and host interface are needed? Identify the server end of the connection ConnectX / BlueField host checklist
What must match between two installed ports? Choose separate optics, an integrated cable or a breakout path Optics and cable qualification
Which exact item is being discussed? Preserve the model, ordering number and length suffix Four-part comparison and the linked product pages
What should engineering hand to purchasing? Assign an owner to every unresolved field Link schedule CSV and project brief

Compare twin-port DACs by length and cooling

Model NVIDIA ordering number Length Cooling configuration Logical links
MCP4Y10-N002 980-9IA0I-00N002 2 m Finned at both ends 2 × 400 Gb/s
MCP4Y10-N002-FLT 980-9IA0J-00N002 2 m Flat at both ends 2 × 400 Gb/s
MCP4Y10-N001-FTF 980-9IA0H-00N001 1 m One flat top and one finned top 2 × 400 Gb/s

Each is a single point-to-point cable with 800 Gb/s aggregate bandwidth across two 400 Gb/s links. Keep the full model and ordering code on the BOM. For the 1 m flat-to-finned cable, record which endpoint needs each top style. Verify the cooling requirements and supported port modes at both cages before quoting. NVIDIA DAC ordering information · NVIDIA cable table with the FTF variant

Choose the 3 m crossover by optical branch count

Model NVIDIA ordering number OM3 Type B cable path
MFP7E10-N003 980-9I73U-000003 One four-channel end to one four-channel end. Both ends are female MPO-12/APC.
MFP7E20-N003 980-9I571-00N003 One four-channel end to two two-channel branches. All three ends are female MPO-12/APC.

For a proposed 400G to 2 × 200G link, use the E20 topology and confirm that the chosen optical modules and hosts support the required lane and port modes. OSFP and QSFP112 identify module form factors. Check the actual optical receptacles before mating the cable. NVIDIA 3 m ordering table · E10 specifications · E20 specifications

Match length, order code and port layout on the purchase order

Route requirement Exact catalog item Check before accepting
40 m single-mode, MPO12/APC to MPO12/APC MFP7E30-N040 · 980-9I580-00N030 The OPN ends in 030; NVIDIA’s ordering row still specifies 40 m.
60 m single-mode, same ends MFP7E30-N060 · 980-9I581-00N050 Check model, full OPN and length on the label.
70 m single-mode, same ends MFP7E30-N070 · 980-9I582-00N050 Different from the 60 m assembly despite the same last digits.
1 m copper, OSFP to dual QSFP112 MCP7Y10-N001 · 980-9I928-00N001 Confirm the two QSFP112 branches and the supported port mode.
MMC12/APC to dual MPO12/APC MFP7E70-X005 · 980-9IB30-00X005 Get the exact drawing and match all three ends. The illustration does not establish the lane map.

Read the NVIDIA single-mode order-code rows, then compare MPO/MMC assembly options. Record the intended path and actual measured loss at each mate.

From a product family to a useful request

For a separate-optics path, list the two modules and every fiber segment. For a DAC or AOC, keep the complete assembly identity. For breakout, name the parent port and each branch. Use the NVIDIA LinkX product-line overview to understand the family, then check the exact component and endpoint documentation.

A filled schedule should let another person answer: what connects to what, which values are confirmed, who will resolve the gaps, and which check releases the line for purchasing. Send the list you already have; the detailed article below explains how to work through the connection.

Choose AI Network Cables by the Complete Link

A cable selection starts with two endpoints and an intended operating mode. Product names such as OSFP, 800G or splitter describe only part of the requirement.

NVIDIA’s LinkX overview groups passive copper, active copper, optical cables, transceivers and fiber assemblies within a wider adapter-and-switch ecosystem. That family description is a starting point, not proof that any two parts form a supported link. LinkX ecosystem overview

Write one link record before selecting a part

Capture the source device and physical port, destination device and port, protocol, target rate, lane mapping, approximate routed distance and rack environment. Add the software and firmware releases that will be used during acceptance.

For breakout links, draw each branch and its destination. Count logical links separately from connector cages. A purchase list with the right total bandwidth can still contain the wrong fan-out.

Check the physical and optical boundaries

Verify the thermal design at both endpoints, including the required heatsink arrangement. Record fiber type, connector, polish, polarity and supported reach for the exact transceiver pair. Do not infer compatibility from a connector that appears to fit.

A management link should be selected against its own endpoint requirements. A 1GbE module has a different purpose from the GPU fabric; it should not inherit an AI-performance claim merely because both appear in the same project.

Apply port-specific restrictions

Some restrictions apply to particular ports, not the entire switch family. For example, NVIDIA’s Q3200 guidance excludes split mode and specified LACC parts on ports 17, 18, 35 and 36. Read the exact list and relevant release before wiring. This Q3200 example must not be generalized to another switch. Q3200 design constraints

Verify lifecycle as well as compatibility

A supported-products table can contain engineering samples alongside general-availability parts. NVIDIA’s ConnectX-9 table explicitly separates these lifecycle categories. A row’s presence therefore does not establish commercial readiness. Versioned compatibility and lifecycle table

Close with a documented acceptance test

After installation, confirm device recognition, negotiated rate, error counters and sustained traffic on every intended path. Exercise breakout branches individually and together. Save serial numbers, labels and results so a replacement can be checked against the same baseline.

The final bill of materials should contain complete order codes and approved alternatives. If the title, ordering row and support matrix disagree, keep the affected field unresolved until the manufacturer clarifies it. A historical deployment or a family-level case study cannot resolve an exact-part conflict.

Sources checked: 10 October 2026. This article discusses third-party evidence or an explicitly labeled engineering scenario; it does not establish a reseller’s delivery history, current stock or exact-SKU deployment.

Turn the selected topology into a purchase line

Decision Confirmed example Information still needed for the project
100G separate optics MMA1B00-C100D: QSFP28 SR4, MPO/UPC; 70 m OM3 or 100 m OM4 at 100GbE Both host ports and firmware; fiber grade and complete channel loss
400G separate optics MMA4Z00-NS400-T: flat-top single-port OSFP, MPO-12/APC; 30 m OM3 or 50 m OM4 Cage cooling, opposite module and panel count; the 50 m OM4 description assumes two optical patch panels
One-to-one fiber path MFP7E10-N003: 3 m straight crossover, four-channel MPO/APC at both ends Port-to-port mapping and polarity
One parent and two branches MFP7E20-N003: 3 m 1:2 splitter crossover, four-channel parent to two two-channel branches Supported parent breakout mode and both receiving-port modes

These rows are separate selection examples, not an interchangeable set. The UPC 100G module must not be directly mated to these APC assemblies. A passive splitter routes channels; it does not convert modulation. The linked product pages retain the exact ordering numbers and manufacturer references.

Give purchasing one row per logical link: source and destination device/port, module PN, cable PN and length, branch label, quantity (or undecided), destination and acceptance owner. Download the link schedule, compare the AI Ethernet fabric plan, or send an incomplete project request. Missing equipment or quantities can be explained in the request; no compatibility result is implied by submitting it.

Technical illustrations

Choose AI Network Cables by the Complete Link — technical illustration 1

Choose AI Network Cables by the Complete Link — technical illustration 2

Related engineering scenarios

Practical project worksheets

Download only what helps your task. You can send your existing list now and add missing details later. Worksheets are in English.

Tags:NVIDIA networking